Instructions for Use

Technical specifications

Listed below is the technical information regarding the MESI ABPI MD and its on-delivery specifications.

3.1 MESI ABPI MD

3.1.1 DIMENSIONS

DIMENSIONS
Column AColumn B
Width223 mm / 8.78 in
Height174 mm / 6.85 in
Depth86 mm / 3.38 in
Weight1000 g / 2.2 lbs

3.1.2 POWER & BATTERY

Power & Battery
Column AColumn B
Battery typeRechargeable Lithium-Polymer battery
Capacity4400 mAh
AC/DC adaptorFRIWO FW8030M/05 or FOX NEO30-XM
Input100-240 V AC / 50-60 Hz / 600-300 mA
Output5V DC / 3.0 A
Examinations per battery charge> 100
Charge time for depleted battery2 hours

3.1.3 CUFF SIZES

Cuff sizes
Column AColumn B
Medium size cuffsABPIMDACFFBRM, ABPIMDACFFBLM, ABPIMDACFFALM, ABPIMDACFFARM
Circumference22-32 cm
Large size cuffsABPIMDACFFBRL, ABPIMDACFFBLL, ABPIMDACFFALL, ABPIMDACFFARL
Circumference32-42 cm
RIGHT ARMred
LEFT ARMyellow
RIGHT ANKLEblack
LEFT ANKLEgreen

3.2 CLASSIFICATION

Protection against electric shock: Class II

Medical device classification: Class IIa

Applied parts (cuffs for arms and ankles): Type BF Applied part

Software classification: Class A

RF emissions (CIPSR 11): Group 1. Class B

3.3 OPERATING, TRANSPORTING AND STORAGE CONDITIONS

Operating Conditions
Column AColumn B
Temperature, operating10° to 40°C ( 50° to 104°F)
Relative humidity30 to 80% (no condensation)
Pressure during operation700 to 1060 hPa
Ingress protection ratingIP2X rating
Transport & Storage Conditions
Column AColumn B
Temperature0° to 40°C (32° to 104°F)
Relative humidity15 to 85%
Pressure during storage700 to 1060 hPa
Ingress protection ratingIP2X rating

⚠️If the device is used or stored outside the specified environmental parameters, the accuracy specified within the technical specifications of the device is not guaranteed.

3.4 MEASUREMENT SPECIFICATIONS

Measurements using oscillometry and volume plethysmography:

  • Ankle-Brachial Pressure Index

  • Systolic blood pressure

  • Diastolic blood pressure

  • Mean average blood pressure

  • Heart rate

Measurement range:

  • Pressure: 0 to 299 mmHg

  • Pulse rate: 30 to 199 beats per minute

Max deviation:

  • Pressure: ± 3 mmHg

  • Heart rate: ± 5% of value

  • Ankle-Brachial Pressure Index: ± 0.1

3.5 CONNECTIVITY

The USB type C port is meant only for connecting the device to a PC (via the USB cable enclosed in the packaging box) in order to transfer of the measurement data. The port is not meant to be used for connecting it with other USB type C cables or chargers.